Furnace Not Heating

A furnace that has stopped heating is rarely worn out. A setting, a switch, a dirty filter or a single worn ignition part has usually stopped it, and how the furnace behaves tells you where to look.

  • Upfront pricing
  • Same-day service
  • Diagnostic fee waived

A furnace that isn’t heating has usually been stopped by something small: a thermostat setting, a clogged filter, a switch that’s off, a pilot that has gone out, or a single worn ignition part. Less often the blower motor or the gas supply is to blame. Before you call, notice how the furnace behaves, because each pattern points somewhere different.

Gas smell? Leave right away. Don’t flip switches or touch the thermostat on the way out, and phone the gas company or 911 once you’re outside. CO alarm sounding? Everyone leaves the house, and you call 911 from outside.

When nothing happens at all

No blower, no clicks, no hum. The furnace is either without power or not receiving a call for heat. Start with the thermostat (Heat mode, set above room temperature, fresh batteries), then the breaker and the power switch mounted near the furnace. Most furnaces also have a safety switch behind the blower door: if the panel was removed for a filter change and not pushed fully home, the furnace won’t run. When all of that checks out, suspect a blown low-voltage fuse, a failed transformer or a bad control board.

When the fan blows cold air

Look at the thermostat’s fan setting first. In the On position the blower never rests, so between burner cycles it circulates unheated air; Auto is what you want. With the fan on Auto and the air still cold, the burners aren’t lighting or aren’t staying lit. On a modern furnace that points to the igniter, the gas valve, a pressure switch or a dirty flame sensor, and our page on a furnace that won’t ignite walks through each. Older furnaces that keep a small pilot flame burning may simply have lost it.

When it heats, but not enough

The burners light and warm air comes out, yet the house won’t warm up or some rooms lag far behind. Typical reasons: a clogged filter that lets the furnace overheat and shut its burners off early, a weak blower motor, closed or blocked registers, and leaky or disconnected ducts dumping heat into the attic or crawlspace. If the burners keep stopping and restarting every few minutes, see furnace short cycling.

When it tries and gives up

You hear the furnace start, perhaps a click or an orange glow, then it stops and tries again. After a few failed attempts most furnaces lock out for a while. A flashing LED behind the small window in the furnace door usually gives a code; note the pattern before you cut power, because switching off clears it.

At a glance

What you noticeLikely causeWhat it takes
Blower runs all day, air never warmsThermostat fan left on OnReturn the fan to Auto
Dead silent, no lightsPower off, blower door switch open, board fuse or transformerSwitch or breaker; electrical diagnosis
Igniter glows orange, burners stay darkGas shut off at the valve, valve failure, supply outageValve check; testing or a utility call
Burners catch, then drop out within secondsFlame sensor coated or wornClean or replace the sensor
Pilot goes out or won’t relightThermocouple or pilot assemblyThermocouple replacement
Warm air, very little of itClogged filter, failing blower motorNew filter; motor or capacitor repair
Hot air at the furnace, cool rooms down the hallDuct joints separated or leakingDuct sealing or reconnection

Safe checks for you

  1. Thermostat: Heat mode, three or four degrees warmer than the room, fan on Auto, weak batteries replaced.
  2. Filter: if it’s grey or caked, put in a new one. Standard filters typically need it every one to three months.
  3. Power: the breaker, and the furnace’s own power switch.
  4. Blower door: seated firmly so its safety switch closes.
  5. Gas: the handle on the gas valve beside the furnace should run parallel to the pipe. If the stove and water heater have no gas either, the supply is out; call the gas company.
  6. Pilot (older furnaces only): relight it with the instructions printed on the furnace, and only if there’s no gas smell.
  7. Registers and returns: open and unblocked.

Stop and call when

  • the furnace still won’t heat after those checks, or locks itself out a second time;
  • the pilot won’t stay lit, or the burners light with a bang;
  • you see black soot marks near the furnace or a lazy yellow flame;
  • a technician has told you the heat exchanger may be cracked. Then the furnace stays off: don’t restart it, because a crack can leak carbon monoxide into the house.

Anything inside the burner compartment is technician work: the igniter, flame sensor, gas valve, control board and blower motor. Our technician runs the furnace through its start-up, measures gas pressure and the flame signal, checks airflow, and inspects the flue and heat exchanger before quoting a price.

Furnace repair costs

Most furnace repairs fall between $89 and $600, with larger parts running higher. Flame sensor cleaning, igniters and thermocouples sit toward the lower end; blower motors, gas valves and control boards cost more. The diagnostic fee is waived if you go ahead. A yearly furnace tune-up, $89 to $199, is the usual way to catch a dirty sensor or a tired igniter before the first cold night.

Older San Jose ducts

Many older San Jose homes, including plenty in Cambrian and Willow Glen, still have original ductwork in the attic or crawlspace. When the furnace runs normally but the house stays cool, a separated or leaking duct is a common reason, and a new furnace wouldn’t fix it.

Common questions

Why won't my furnace turn on at all?

Look at the thermostat mode and batteries, the furnace breaker, the power switch near the furnace, and whether the blower door is seated. If all of those are fine, the ignition system, a safety switch or the control board is the likely cause.

Can I relight the pilot light myself?

On an older furnace with a standing pilot, yes, by following the lighting steps printed on the furnace and only if there's no gas smell. If the pilot won't stay lit, the thermocouple or gas valve needs a technician.

What do furnace noises mean?

A bang as the burners light usually means delayed ignition and should be checked soon. A squeal can be a belt or a blower bearing, and a rumble can point to a burner problem.

How often should I change the furnace filter?

Standard filters every one to three months, sooner with pets, allergies or heavy use. Thicker filters last longer, but look at them monthly.

Is a cracked heat exchanger dangerous?

Yes. A crack can leak carbon monoxide into the house. If one is suspected, leave the furnace off and don't restart it until a technician has inspected it.